The Customize section of the system contains the additional setup
parameters. The appropriate Value fields in the Advanced Transmission
Parameters
screen should be changed as required.

Figure 9.

BTI Advanced Transmission Screen for setting IP path to AMC. (Note the

address 192.168.0.68 is shown as an example only. Also note the forward slash /
separating the IP and the folder name “incoming”)

6. Full pathname of ftp Site: Enter the full path to the AMC in the form of

xxx.xxx.xxx.xxx/incoming where the x’s represent the AMC’s IP
address.

7. filename (no Extension): Default = Alert. Can be modified if necessary,

otherwise leave as default value.

8. ftp User login: Default = anonymous. Can be modified if necessary,

otherwise leave as default value.

9. ftp User password: Default = anonymous. Can be modified if

necessary, otherwise leave as default value.

10. Contact to close to play alert tones (0-7): User selectable. Stations

using the BTI Contact Closure (GPO) unit may choose an open contact to
wire to the MultiPlayer to control audio playback

Optional GPI/O wiring to the AMC:
A. Wire (2-wires) the selected GPO from BTI Attendant Solutions to

one or more of the GPI’s on the MultiPlayer.

B. In the AMC Configuration > GPIO page assign the input to “Play

All” (Note you can label the input “BTI” making it easy to identify
the input source)

C. Click “Update” to save the configuration

11. number of seconds to keep the contact closed: Default = 60. Can be

modified if necessary, otherwise leave as default value

12. Click Close then Close again