39

Digital Audio

Input Port Select: This is where you can switch between the coaxial S/PDIF digital input and

the XLR AES/EBU digital input for each of the 4 digital inputs available in
each format.

PLL status: Shows if an S/PDIF (or AES/EBU) connection is made. If Lock is displayed, an

S/PDIF (or AES/EBU) signal is detected at the specific input. If Unlock is
displayed, no signal is detected.

Format: - Professional (IEC 958 Type 1): EX8000 digital in/out format is AES/EBU.

- Consumer (IEC 958 Type II): EX8000 digital in/out format is S/PDIF.

Note that you can set this to Professional but keep the RCA (S/PDIF) port. This would
allow you to process an AES/EBU signal coming in on an unbalanced S/PDIF cable.

Analog Output Level Control: This is where you can control the analog output level for each

playback / output channel.