Flowserve Type R User Manual

Page 8

Advertising
background image

R and RX SLURRY Pump USER INSTRUCTIONS ENGLISH

71569242 03-11 (E)

Page 8 of 54

®

Avoid electrostatic charge: do not rub non-metallic

surfaces with a dry cloth

;

ensure cloth is damp.


For ATEX application the coupling must be selected to
comply with 94/9/EC. Correct coupling alignment must
be maintained.

Additional requirement for metallic pumps on non-
metallic baseplates
When metallic components are fitted on a non-metallic
baseplate they must be individually earthed.

1.6.4.6 Preventing leakage

The pump must only be used to handle liquids for

which it has been approved to have the correct
corrosion resistance.

Avoid entrapment of liquid in the pump and associated
piping due to closing of suction and discharge valves,
which could cause dangerous excessive pressures to
occur if there is heat input to the liquid. This can occur if
the pump is stationary or running.

Bursting of liquid containing parts due to freezing must
be avoided by draining or protecting the pump and
ancillary systems.

Where there is the potential hazard of a loss of a seal
barrier fluid or external flush, the fluid must be
monitored.

If leakage of liquid to atmosphere can result in a
hazard, install a liquid detection device.

1.6.4.7 Maintenance to avoid the hazard

CORRECT MAINTENANCE IS REQUIRED TO

AVOID POTENTIAL HAZARDS WHICH GIVE A RISK
OF EXPLOSION

The responsibility for compliance with maintenance
instructions is with the plant operator.

To avoid potential explosion hazards during
maintenance, the tools, cleaning and painting materials
used must not give rise to sparking or adversely affect
the ambient conditions. Where there is a risk from
such tools or materials, maintenance must be
conducted in a safe area.

It is recommended that a maintenance plan and
schedule is adopted. (See section 6, Maintenance.)


Advertising
This manual is related to the following products: