Motor size
and speed

kW (hp)

Typical sound pressure level LpA at 1 m reference 20 μPa, dBA

3550 r/min

2900 r/min

1750 r/min

1450 r/min

Pump

only

Pump and

motor

Pump

only

Pump and

motor

Pump

only

Pump and

motor

Pump

only

Pump and

motor

<0.55 (<0.75)

58

65

50

58

50

52

50

52

0.75 (1)

60

65

52

59

51

54

51

54

1.1 (1.5)

62

67

54

60

55

57

53

56

1.5 (2)

63

66

55

63

56

59

54

58

2.2 (3)

64

69

57

65

58

62

56

60

3 (4)

63

71

58

68

59

64

57

62

4 (5)

64

72

60

69

61

65

59

63

5.5 (7.5)

66

73

62

71

63

67

61

65

7.5 (10)

67

73

63

71

64

69

62

67

11 (15)

69

76

65

73

66

71

64

69

15 (20)

71

77

67

74

68

72

66

70

18.5 (25)

72

78

68

75

69

70

67

70

22 (30)

73

78

69

76

70

71

68

71

30 (40)

75

79

71

77

72

72

70

72

37 (50)

76

80

72

78

73

73

71

73

45 (60)

77

81

73

79

74

74

72

74

55 (75)

78

81

74

79

75

75

73

75

75 (100)

80

83

76

81

77

76

75

76

90 (120)

81

84

77

81

78

77

76

77

110 (150)

82

85

78

82

79

78

77

78

150 (200)

84

87

80

84

81

79

79

79

200 (270)

81

81

79

79

300 (400)

83

86

81

82

The noise level of machines in this range will most likely be of values which require noise exposure control, but typical values are inappropriate.

Note: for 1 180 and 960 r/min reduce 1 450 r/min values by 2 dBA. For 880 and 720 r/min reduce 1 450 r/min values by 3 dBA.

2

TRANSPORT AND STORAGE

2.1

Consignment receipt and

unpacking

Immediately after receipt of the equipment it must be
checked against the delivery/shipping documents for
its completeness and that there has been no damage
in transportation. Any shortage and/or damage must
be reported immediately to Flowserve and must be
received in writing within one month of receipt of the
equipment. Later claims cannot be accepted.

Check any crate, boxes or wrappings for any
accessories or spare parts that may be packed
separately with the equipment or attached to side
walls of the box or equipment.

Each product has a unique serial number. Check
that this number corresponds with that advised and
always quote this number in correspondence as well
as when ordering spare parts or further accessories.

2.2

Handling

Boxes, crates, pallets or cartons may be unloaded
using fork lift vehicles or slings dependent on their
size and construction.

2.3

Lifting

A crane must be used for all pump sets or

components in excess of 25 kg (55 lb.). Fully trained
personnel must carry out lifting, in accordance with
local regulations.

Slings, ropes and other lifting gear should be
positioned where they cannot slip and where a
balanced lift is obtained. The angle between sling or
ropes used for lifting must not exceed 60°.

2.3.1

Bare pump

The bare pump should be lifted as shown:

Advertising