g)

Remove bearing housing assembly from pump
casing [1100].

h)

The two threaded holes in the adaptor flange can
be used for jacking screws to assist with removal.

i)

Remove pump casing gasket [4590.1] and discard. A
replacement gasket will be required for assembly.

j)

Clean gasket mating surfaces.


6.8.2

Impeller removal

NEVER APPLY HEAT TO REMOVE THE

IMPELLER. TRAPPED OIL OR LUBRICANT MAY
CAUSE AN EXPLOSION.

Impeller removal with threaded on

6.8.2.1
impeller/locking screw
a)

Ensure the pump bearing housing assembly is
firmly fixed to the work bench.

b)

Fit a chain wrench or bolt a bar to the holes in the
coupling half, or fit a keyed shaft wrench directly to
the shaft. Make sure the wrench or bar cannot slip.

c)

Unscrew the locking screw [6570.6] in the impeller
hub completely (applicable only on the locking
screw configuration).

d) Turn the shaft [2100] counter-clockwise as viewed

from the drive end of the shaft with the wrench.

e)

Give the shaft a quick turn clockwise to sharply
strike the wrench handle against the work bench
surface or a wooden block. A few sharp strikes by
the handle onto the bench/wooden block will free
the impeller from the shaft.

f)

Alternatively, twist the impeller by firmly grabbing
hold of the impeller and twist it counter-clockwise.
To make the wrench handle impact on the work
bench. This method requires the use of metal
mesh reinforced gloves.

g)

Remove and discard the impeller O-ring [4610.1].
Use a new O-ring for assembly.

Impeller removal with key drive impeller

6.8.2.2
c) Remove impeller nut [2912.1/2912.2] complete with

O-ring [4610.5], which should be discarded. (A new
O-ring will be required for assembly.)

d)

Pull impeller [2200] off shaft [2100].

e)

Remove impeller key [6700.2].

f)

Remove impeller sealing gasket [4590.4] and discard.
(A new sealing gasket will be required for assembly.)


6.8.3

Cover and seal

The seal manufacturer's instructions should be followed
for dismantling and assembly, but the following guidance
should assist with most seal types:
a)

Remove shaft guard (if fitted).

b)

Remove the seal gland nuts, if a separate seal
gland is fitted, and slide the seal gland away.
Remove the two cover nuts [6580].

c)

Loosen the grub screws (used in most mechanical
seals).

d)

Carefully pull off the cover and mechanical seal
rotating element(s).

e)

Remove the seal cover.

f)

Remove shaft sleeve (if fitted).

g)

On non-cartridge seals the stationary seat remains
in the cover/mechanical seal gland with its sealing
member. Remove only if damaged or worn out.

h)

On pumps fitted with gland packing, the packing
and lantern ring should be removed only if the
packing is to be replaced.


6.8.4

Bearing housing

a) Take grub screw(s) out of the pump half coupling and

pull off this coupling and remove the coupling key.

b)

Remove support foot [3134] (if necessary).

c) Remove the pump side liquid deflector [2540] and/or

labyrinth seal rotary half (depending on option fitted).

d) Slacken the bearing carrier screws

to initiate bearing

carrier release.

e) Remove bearing carrier [3240] and shaft [2100]

assembly from the bearing housing [3200] by pulling it
towards the coupling end.

f) Remove bearing circlip [6544] (or bearing lock nut

[3712.2] if paired angular contact bearings are fitted).

B

earing carrier locking rings are left-hand

thread.

g)

Remove drive side v-ring [4305] and/or labyrinth
seal rotary half (depending on option fitted).

h)

Remove bearing carrier [3240].

i)

Remove pump side bearing [3011].

j)

Release the self-locking drive side bearing nut
[3712.1] and remove drive side bearing [3013].

k)

When pressing bearings off the shaft, use force on
the inner race only.

6.9

Examination of parts

Used parts must be inspected before

assembly to ensure the pump will subsequently run
properly. In particular, fault diagnosis is essential to
enhance pump and plant reliability.

6.9.1

Casing, cover and impeller

Inspect for excessive wear, pitting, corrosion, erosion or
damage and any sealing surface irregularities. Replace
as necessary.

6.9.2

Shaft and sleeve (if fitted)

Replace if grooved or pitted. With the bearing mounting
diameters (or bearing outer) supported by V-blocks, check
that the shaft runouts are within 0.025 mm (0.001 in.) at
the coupling end and 0.050 mm (0.002 in.) at the
sleeve/impeller end.