Transport and storage, Consignment receipt and unpacking, Handling – Flowserve IDP CPXV User Manual

Page 10: Lifting, Handling (2.2), Lifting (2.3), 2transport and storage, 1 consignment receipt and unpacking, 2 handling, 3 lifting

Advertising
background image

CPXV and CPXRV USER INSTRUCTIONS ENGLISH 71569193 09-14

Page 10 of 48

flowserve.com

For estimating sound power level L

WA

(re 1 pW) then

add 14 dBA to the sound pressure value.

Motor size
and speed

kW (hp)

Typical sound pressure level L

pA

at 1 m reference 20 μPa, dBA

3 550 r/min

2 900 r/min

1 750 r/min

1 450 r/min

Pump

only

Pump and

motor

Pump

only

Pump and

motor

Pump

only

Pump and

motor

Pump

only

Pump and

motor

<0.55 (<0.75)

72

72

64

65

62

64

62

64

0.75 (1)

72

72

64

66

62

64

62

64

1.1 (1.5)

74

74

66

67

64

64

62

63

1.5 (2)

74

74

66

71

64

64

62

63

2.2 (3)

75

76

68

72

65

66

63

64

3 (4)

75

76

70

73

65

66

63

64

4 (5)

75

76

71

73

65

66

63

64

5.5 (7.5)

76

77

72

75

66

67

64

65

7.5 (10)

76

77

72

75

66

67

64

65

11 (15)

80

81

76

78

70

71

68

69

15 (20)

80

81

76

78

70

71

68

69

18.5 (25)

81

81

77

78

71

71

69

71

22 (30)

81

81

77

79

71

71

69

71

30 (40)

83

83

79

81

73

73

71

73

37 (50)

83

83

79

81

73

73

71

73

45 (60)

86

86

82

84

76

76

74

76

55 (75)

86

86

82

84

76

76

74

76

75 (100)

87

87

83

85

77

77

75

77

90 (120)

87

88

83

85

77

78

75

78

110 (150)

89

90

85

87

79

80

77

80

150 (200)

89

90

85

87

79

80

77

80

200 (270)

85

87

83

85

300 (400)

87

90

85

86

The noise level of machines in this range will most likely be of values which require noise exposure control, but typical values are inappropriate.

Note: for 1 180 and 960 r/min reduce 1 450 r/min values by 2 dBA. For 880 and 720 r/min reduce 1 450 r/min values by 3 dBA.

2

TRANSPORT AND STORAGE

2.1 Consignment receipt and unpacking

Immediately after receipt of the equipment it must be
checked against the delivery/shipping documents for
its completeness and that there has been no damage
in transportation. Any shortage and/or damage must
be reported immediately to Flowserve and must be
received in writing within one month of receipt of the
equipment. Later claims cannot be accepted.

Check any crate, boxes or wrappings for any
accessories or spare parts that may be packed
separately with the equipment or attached to side
walls of the box or equipment.

Each product has a unique serial number. Check
that this number corresponds with that advised and
always quote this number in correspondence as well
as when ordering spare parts or further accessories.

2.2 Handling

Boxes, crates, pallets or cartons may be unloaded
using fork lift vehicles or slings dependent on their
size and construction.

2.3 Lifting

A crane must be used for all pump sets in

excess of 25 kg (55 lb). Fully trained personnel must
carry out lifting, in accordance with local regulations.

Pumps with drivers over approximately 7.5 kW, are
supplied with the pump packed as a separate item
from the driver. These should be lifted separately
into their installed position, using lifting points on the
pump sole plate, and on the motor.

When lifting pumps with drivers fitted,

the resulting center of gravity may be above the lifting
points, and the method of slinging must prevent the
machine tipping during the lift.

Advertising