CPXV and CPXRV USER INSTRUCTIONS ENGLISH 71569193 09-14

Page 6 of 48

flowserve.com

HAZARDOUS LIQUIDS

When the pump is handling hazardous liquids care
must be taken to avoid exposure to the liquid by
appropriate siting of the pump, limiting personnel
access and by operator training. If the liquid is
flammable and or explosive, strict safety procedures
must be applied.

Gland packing must not be used when pumping
hazardous liquids.

PREVENT EXCESSIVE EXTERNAL

PIPE LOAD
Do not use pump as a support for piping. Do not mount
expansion joints, unless allowed by Flowserve in
writing, so that their force, due to internal pressure, acts
on the pump flange.

NEVER RUN THE PUMP DRY

Liquid level controls are recommended to avoid the risk
of dry running.

ENSURE CORRECT LUBRICATION

(See section 5, Commissioning, start-up, operation and
shutdown
.)

ONLY CHECK DIRECTION OF

MOTOR ROTATION WITH COUPLING ELEMENT/
PINS REMOVED
Starting in reverse direction of rotation will damage the
pump.

START THE PUMP WITH OUTLET

VALVE PART OPENED
(Unless otherwise instructed at a specific point in the
User Instructions.)
This is recommended to minimize the risk of
overloading and damaging the pump or motor at full or
zero flow. Pumps may be started with the valve further
open only on installations

where this situation cannot

occur. The pump outlet control valve may need to be
adjusted to comply with the duty following the run-up
process. (See section 5, Commissioning start-up,
operation and shutdown
.)

DO NOT RUN THE PUMP AT

ABNORMALLY HIGH OR LOW FLOW RATES
Operating at a flow rate higher than normal or at a flow
rate with no back pressure on the pump may overload
the motor and cause cavitation. Low flow rates may
cause a reduction in pump/bearing life, overheating of
the pump, instability and cavitation/vibration.

1.6.4

Products used in potentially explosive

atmospheres

Measures are required to:

Avoid excess temperature

Prevent build up of explosive mixtures

Prevent the generation of sparks

Prevent leakages

Maintain the pump to avoid hazard


The following instructions for pumps and pump units
when installed in potentially explosive atmospheres
must be followed to help ensure explosion protection.
For ATEX, both electrical and non-electrical equipment
must meet the requirements of European Directive
2014/34/EU (previously 94/9/EC which remains valid
until 20 April 2016 during the transition). Always
observe the regional legal Ex requirements e.g. Ex
electrical items outside the EU may be required certified
to other than ATEX e.g. IECEx, UL.

1.6.4.1 Scope of compliance

Use equipment only in the zone for which it is

appropriate.

Always check that the driver, drive

coupling assembly, seal and pump equipment are
suitably rated and/or certified for the classification of the
specific atmosphere in which they are to be installed.

Where Flowserve has supplied only the bare shaft
pump, the Ex rating applies only to the pump. The
party responsible for assembling the ATEX pump set
shall select the coupling, driver and any additional
equipment, with the necessary CE Certificate/
Declaration of Conformity establishing it is suitable for
the area in which it is to be installed.

The motor, coupling, pump thrust bearing and seal
can be made compliant with ATEX Directive
2014/34/EU (previously 94/9/EC which remains valid
until 20 April 2016 during the transition) for
Equipment Categories 2 and 3 as required by the
duty conditions.

See the pump nameplate and Declaration of Conformity
for the pump classification. The pump column below
sole plate will also generally be to the same category
however in some applications the section of the pump
below sole plate and above liquid will have been
designed to Category 1, whereas above sole plate
Category 2 or 3 will apply. (See section 1.6.4.2.)