HED/HED-DS USER INSTRUCTIONS ENGLISH 85392695 – 06/14

Page 32 of 64

Immediately after start up, and frequently during
running check the following:

a) Check suction and discharge pressure gauges.
b) Check pressure gauges on each side of suction

strainer.

c) Check for excessive leakage at seal areas.
d) Check for unusual noises.
e) Check oil level in bearing housing. (Refer to

Section 5).

Operation of the unit without correct

lubrication can result in overheating of the
bearings, bearing failures, pump seizures and
actual break-up of the equipment exposing
operating personnel to physical injury.

f) Check for vibrations.
g) Check for adequate flow of cooling liquids.
Check for hot alignment: for services 55 °C ( 100 °F)
and more above ambient, after unit has been
operated a sufficient period of time to reach normal
operating temperature and condition, the unit is to be
shut down and a "HOT" coupling alignment check
must be made (Refer to Section 4.5.4).

5.7.1 Venting the pump

Vent the pump to enable all trapped air to

escape taking due care with hot or hazardous liquids.

Under normal operating conditions, after the pump
has been fully primed and vented, it should be
unnecessary to re-vent the pump.

5.7.2 Pumps fitted with mechanical seal
Mechanical seals require no adjustment. Any slight
initial leakage will stop when the seal is run in.

Before pumping dirty liquids it is advisable, if
possible, to run in the pump mechanical seal using
clean liquid to safeguard the seal face.

External flush or quench should be

started before the pump is run and allowed to flow for
a period after the pump has stopped.

Never run a mechanical seal dry, even

for a short time.

5.7.3 Bearings

If the pumps are working in a potentially

explosive atmosphere temperature or vibration
monitoring at the bearings is recommended


If bearing temperatures are to be monitored it is
essential that a benchmark temperature is recorded
at the commissioning stage and after the bearing
temperature has stabilized (see 5.2.4.1 for
temperature limits).
When a oil temperature sensor is provided:

 set the alarm at 82 °C (180 °F) and the trip at 90

°C (194 °F) for high ambient temperature and/or
hot service

When the bearing temperature sensor is provided:
 set the alarm at 93 °C (180 °F) and the trip at 105

°C (200 °F)


It is important, to keep a check on bearing
temperatures. After start up the temperature rise
should be gradual, reaching a maximum after
approximately 1.5 to 2 hours. This temperature rise
should then remain constant or marginally reduce
with time.

5.7.4 Normal vibration levels, alarm and trip
For guidance, pumps generally fall under a
classification for rigid support machines within the
International rotating machinery standards and the
recommended maximum levels below are based on
those standards.

Alarm and trip values for installed

pumps should be based on the actual measurements
(N) taken on the pump in the fully commissioned as
new condition. Measuring vibration at regular
intervals will then show any deterioration in pump or
system operating conditions.

Vibration velocity – unfiltered
mm/s (in./s) r.m.s.

HED/HED-DS

mm/s (in./s) r.m.s.

Normal

N

 5 (0.2)

Alarm

N x 1.25

 6.2 (0.25)

Shutdown trip

N x 2.0

 10 (0.4)


5.7.5 Stop/start frequency
Pump sets are normally suitable for the number of
equally spaced stop/starts per hour shown in the
table below. Check actual capability of the driver and
control/starting system before commissioning.

Motor rating kW (hp)

Maximum stop/starts

per hour

Up to 15 (20)

15

Between 15 (20) and 90 (120)

10

Above 90 (120)

6

Where duty and standby pumps are installed it is
recommended that they are run alternately every
week.