ESP3 USER INSTRUCTIONS ENGLISH 26999943 08-11

Page 37 of 64


5.10.5 Minimum submergence
Each ESP3 pump has a minimum submergence
depending on the design conditions of that pump.
See Figure 3-6 to determine the minimum
submergence based upon pump flow and suction
size. All minimum submergence values are taken
from the bottom of the strainer.

If a tailpipe [1428] is used, the sump

(pit) liquid level must engulf the casing and adapter
completely during start-up.


6 MAINTENANCE

It is the plant operator's responsibility to ensure

that all maintenance, inspection and assembly work
is carried out by authorized and qualified personnel
who have adequately familiarized themselves with
the subject matter by studying this manual in detail.
(See also section 1.6.)

Any work on the machine must be performed when it
is at a standstill. It is imperative that the procedure
for shutting down the machine is followed, as
described in section 5.9.

On completion of work all guards and safety devices
must be re-installed and made operative again.
Before restarting the machine, the relevant
instructions listed in section 5, Commissioning, start
up, operation and shut down
must be observed.

Oil and grease leaks may make the ground
slippery. Machine maintenance must always
begin and finish by cleaning the ground and the
exterior of the machine.

If platforms, stairs and guardrails are required for
maintenance, they must be placed for easy access to
areas where maintenance and inspection are to be
carried out. The positioning of these accessories
must not limit access or hinder the lifting of the part to
be serviced.

When air or compressed inert gas is used in the
maintenance process, the operator and anyone in the
vicinity must be careful and have the appropriate
protection.

Do not spray air or compressed inert gas on skin.

Do not direct an air or gas jet towards other people.

Never use air or compressed inert gas to clean
clothes.

Before working on the pump, take measures to
prevent the pump from being accidentally started.
Place a warning sign on the starting device:
"Machine under repair: do not start."

With electric drive equipment, lock the main switch
open and withdraw any fuses. Put a warning sign on
the fuse box or main switch:
"Machine under repair: do not connect."

Never clean equipment with flammable solvents or
carbon tetrachloride. Protect yourself against toxic
fumes when using cleaning agents.
Refer to the parts list shown in section 8 for item
number references used throughout this section.

6.1 Maintenance schedule

It is recommended that a maintenance plan and

schedule be implemented, in accordance with these
User Instructions, to include the following:
a) Any auxiliary systems installed must be monitored,

if necessary, to ensure they function correctly.

b) Gland packing must be adjusted correctly to give

visible leakage and concentric alignment of the
gland follower to prevent excessive temperature
of the packing or follower.

c) Check for any leaks from gaskets and seals. The

correct functioning of the shaft seal must be
checked regularly.

d) Check bearing lubricant level, and the remaining

hours before a lubricant change is required.

e) Check that the duty condition is in the safe

operating range for the pump.

f) Check vibration, noise level and surface

temperature at the bearings to confirm
satisfactory operation.

g) Check dirt and dust is removed from areas

around close clearances, bearing housings and
motors.


6.1.1 Preventive maintenance
The following sections of this manual give
instructions on how to perform a complete
maintenance overhaul. However, it is also important
to periodically repeat the Pre start-up checks listed in
section 5.1. These checks will help extend pump life
as well as the length of time between major
overhauls.

6.1.2 Need for maintenance records
A procedure for keeping accurate maintenance
records is a critical part of any program to improve
pump reliability. There are many variables that can
contribute to pump failures. Often long term and
repetitive problems can only be solved by analyzing
these variables through pump maintenance records.