ESP3 USER INSTRUCTIONS ENGLISH 26999943 08-11

Page 7 of 64


If the operation of the system cannot avoid this
condition, fit an appropriate dry run protection device
(for example liquid detection or a power monitor).

To avoid potential hazards from fugitive emissions of
vapor or gas to atmosphere, the surrounding area
must be well ventilated.

1.6.4.5 Preventing sparks

To prevent a potential hazard from mechanical

contact, the coupling guard must be non-sparking for
Category 2.

To avoid the potential hazard from random induced
current generating a spark, the baseplate must be
properly grounded.

Avoid electrostatic charge. Do not rub non-

metallic surfaces with a dry cloth; ensure the cloth is
damp.

The coupling must be selected to comply with
94/9/EC and correct alignment must be maintained.

Additional requirements for pumps on non-
metallic baseplates

When metallic components are fitted on a non-
metallic baseplate they must be individually earthed.

1.6.4.6 Preventing leakage

Pumps with mechanical seal: The pump must

only be used to handle liquids for which it has been
approved to have the correct corrosion resistance.

Avoid entrapment of liquid in the pump and associated
piping due to closing of suction and discharge valves,
which could cause dangerous excessive pressures to
occur if there is heat input to the liquid. This can occur if
the pump is stationary or running.

Bursting of liquid containing parts due to freezing
must be avoided by draining or protecting the pump
and auxiliary systems.

Where there is the potential hazard of a loss of a seal
barrier fluid or external flush, the fluid must be monitored.

If leakage of liquid to atmosphere can result in a
hazard, install a liquid detection device.


1.6.4.7 Maintenance of the centrifugal pump to
avoid a hazard

CORRECT MAINTENANCE IS REQUIRED TO

AVOID POTENTIAL HAZARDS WHICH GIVE A
RISK OF EXPLOSION

The responsibility for compliance with maintenance
instructions is with the plant operator.

To avoid potential explosion hazards during maintenance,
the tools, cleaning and painting materials used must not
give rise to sparking or adversely affect the ambient
conditions. Where there is a risk from such tools or
materials, maintenance must be conducted in a safe area.

It is recommended that a maintenance plan and schedule
is adopted. (See section 6, Maintenance.)

1.7 Name plate and safety labels


1.7.1 Nameplate
For details of nameplate, see the Declaration of
Conformity
and section 3.

1.7.2 Safety labels

1.8 Specific machine performance

For performance parameters see section 1.5, Duty
conditions. Where performance data has been
supplied separately to the purchaser these should be
obtained and retained with these User Instructions if
required

.

INSTALL AND OPERATE EQUIPMENT IN
ACCORDAND WITH THE INSTRUCTION
MANUAL SUPPLIED SEPARATELY.

ENSURE GUARDS ARE SECURELY IN
PLACE.

ENSURE CORRECT DIRECTION OF
ROTATION.

ENSURE ALL EXTERNAL CONNECTIONS TO
THE PUMP / SHAFT SEALING AND DRIVER
ARE CONNECTED AND OPERATIONAL

FULLY PRIME UNIT AND SYSTEM.
DO NOT RUN UNIT DRY


FAILURE TO FOLLOW THESE PROCEEDURES
MAY RESULT IN PERSONAL INJURY
AND/ OR EQUIPMENT DAMAGE

ESSENTIAL PROCEEDURES BEFORE STARTING:

J218JZ250

J218JZ250

ENSURE CORRECT DRIVER DIRECTION
OR ROTATION WITH COUPLING
ELEMENT / PINS REMOVED: OTHERWISE
SERIOUS DAMAGE MAY RESULT.

VERIFIER LE SENS CORRECT DE
ROTATION DU MOTEUR. POMPE
DESACCOUPLEE / ENTRETOISE
DEMONTEE. NE PAS SUIVRE CETTE
RECOMMANDATION PEUT CONDUIRE A
DE GRAVES DOMMAGES POUR LA POMPE

KONTROLLE VORGESCHRIEBENER
DREHRICHTUNG ! HIERZU
KUPPLUNGSZWISCHENSTÜCK /
KUPPLUNGSBOLZEN ENTFERNEN.
ANDERENFALLS ERNSTHAFTE SCHÄDEN !

ZORG VOOR JUISTE ROTATIERICHTING
VAN DRIJFAS WAARBIJ DE
KOPPELELELMENTEN / PENNEN
VERWIJDERD ZIJN: VERZUM KAN
ERNSTIGE SCHADE TOT GEVOLG HABBEN.

CDC: 603 604 610 612 621 623 624