Flowserve Guardian Sealless Metallic User Manual

Page 14

Advertising
background image

GUARDIAN USER INSTRUCTIONS ENGLISH 71569212 08-11

Page 14 of 68

flowserve.com

Figure 3-6: Temperature limitations, long coupled
pumps

Temperature

Limitations

-73 ºC to -29 ºC

(-100 ºF to -20 ºF)

G or H Series acceptable

Group 1 or 2 pumps acceptable

Review material and elastomer

limitations

Replace iron and steel pressure

containing components with
stainless steel. Contact your
Flowserve representative for details

-29 ºC to 121 ºC

(-20 ºF to 250 ºF)

G or H Series acceptable

Group 1 or 2 pumps acceptable

Review material and elastomer

limitations

121 ºC to 177 ºC

(250 ºF to 350 ºF)

H Series only

Group 1 or 2 pumps acceptable

Review material and elastomer

limitations

177 ºC to 287 ºC

(350 ºF to 550 ºF)

H Series only

Group 1 rated to 287 ºC (550 ºF)

Group 2 rated to 232 ºC (450 ºF)!

Review material and elastomer

limitations

Centerline mounting recommended

for services over 177 ºC (350 ºF)

Labyrinth seals recommended for

services over 218 ºC (425 ºF)

Finned oil cooler recommended for

services over 190 ºC (375 ºF)

Figure 3-7: Temperature limitations, close
coupled pumps (Group 1 only)

Temperature

Limitations

-73 ºC to -29 ºC

(-100 ºF to -20 ºF)

G or H Series acceptable

Review material and elastomer

limitations

Replace iron and steel pressure

containing components with stainless
steel. Contact your Flowserve
representative for details

-29 ºC to 121 ºC

(-20 ºF to 250 ºF)

G or H Series acceptable

Review material and elastomer

limitations

121 ºC to 177 ºC

(250 ºF to 350 ºF)

H Series only

Review material and elastomer

limitations

177 ºC to 204 ºC

(350 ºF to 400 ºF)

H Series only

Maximum allowable process fluid

temperature is 204 ºC (400 ºF)

Review material and elastomer

limitations

Centerline mounting recommended

for services over 177 ºC (350 ºF)



Figure 3-8: Alloy cross-reference chart

Flowserve

material code

Designation

Durco legacy

codes

ACI

designation

Equivalent wrought

designation

ASTM

specifications

Material

Group No.

E3020

Ductile iron

DCI

None

None

A395, Gr. 60-40-18

1.0

E3033

High chrome iron

CR28

None

None

A532 class 3

Cr

E4027

High chrome iron

CR29

None

None

None

Cr

E4028

High chrome iron

CR35

None

None

None

Cr

C3009

Carbon steel

DS

None

Carbon steel

A216 Gr. WCB

1.1

C3062

Durco CF8

D2

CF8

304

A744, Gr. CF8

2.1

C3069

Durco CF3

D2L

CF3

304L

A744, Gr. CF3

2.1

C3063

Durco CF8M

D4

CF8M

316

A744, Gr. CF8M

2.2

C3067

Durco CF3M

D4L

CF3M

316L

A744, Gr. CF3M

2.2

C3107

Durcomet 100

CD4M

CD4MCuN

Ferralium

A995, Gr. CD4MCuN

2.8

C4028

Durimet 20

D20

CN7M

Alloy 20

A744, Gr. CN7M

3.17

C4029

Durcomet 5

DV

None

None

None

2.2

K3005

Durco CY40

DINC

CY40

Inconel

600

A494, Gr. CY40

3.5

K3007

Durco M35

DMM

M351

Monel

400

A494, Gr. M35-1

3.4

K3008

Nickel

DNI

CZ100

Nickel 200

A494, Gr. CZ100

3.2

K4007

Chlorimet 2

DC2

N7M

Hastelloy

B

A494, Gr. N7M

3.7

K4008

Chlorimet 3

DC3

CW6M

Hastelloy

C

A494, Gr. CW6M

3.8

E3042

Durichlor 51

D51

None

None

A518, Gr. 2

No load

E4035

Superchlor

SD51

None

None

A518, Gr. 2

No load

H3004

Titanium

Ti

None

Titanium

B367, Gr. C3

Ti

H3005

Titanium-Pd

TiP

None

Titanium-Pd

B367, Gr. C8A

Ti

H3007

Zirconium

Zr

None

Zirconium

B752, Gr. 702C

Ti

Duriron, Durichlor 51 and Superchlor are registered trademarks of Flowserve Corporation.

Ferralium is a registered trademark of Langley Alloys.

Hastelloy is a registered trademark of Haynes International, Inc.

Inconel and Monel are registered trademarks of International Nickel Co. Inc.

Note: some materials listed above may not be available for use in some parts of Guardian pumps.

Advertising