Figure 4-21: Oil cooler - Group 2 schematic


4.6.5.3

Piping connection - support leg cooling
for centerline mounting option

If the casing is centerline mounted, and the process
temperature is over 178 °C (350 °F), then the casin g
support legs may need to be cooled. Cool water - less
than 32 °C (90 °F) - should be run through the legs at a
flow rate of at least 0.06 l/s (1 gpm) as shown below.

Figure 4-22 Centerline mounting option

4.6.5.4

Piping connection - Heating/cooling fluid
for jacketed/casing

The piping connections for jacketed casings are shown
below. The flow rate of the cooling water - less than
32 °C (90 °F) - should be at least 0.13 l/s (2 gpm) .

Figure 4-23: Jacketed casing connections

Notes:
1. When circulating steam, use top hole for inlet. Both bottom

holes must be plumbed together for outlet, to ensure draining
both sides of jacket.

2. When circulating liquid use both bottom holes as inlets. Use top

hole as outlet.

4.6.5.5

Piping connection - oil mist lubrication
system

The piping connections for an oil mist lubrication
system are shown below in Figures 4-24 and 4-25.

Figure 4-24: Oil mist connections – labyrinth style
oil seals (standard)

Figure 4-25: Oil mist connections – lip seals
(optional)

4.7 Electrical connections

Electrical connections must be made by

a qualified Electrician in accordance with relevant
local national and international regulations.

It is important to be aware of the EUROPEAN

DIRECTIVE on potentially explosive areas where
compliance with IEC60079-14 is an additional
requirement for making electrical connections.

It is important to be aware of the EUROPEAN

DIRECTIVE on electromagnetic compatibility when
wiring up and installing equipment on site. Attention
must be paid to ensure that the techniques used
during wiring/installation do not increase
electromagnetic emissions or decrease the
electromagnetic immunity of the equipment, wiring or
any connected devices. If in any doubt contact
Flowserve for advice.