GUARDIAN USER INSTRUCTIONS ENGLISH 71569212 08-11

Page 58 of 68

flowserve.com

Pump not reaching design flow rate

Pump not reaching design head (TDH)

No discharge or flow with pump running

Pump operates for short period, then loses prime

Excessive noise from wet end

Excessive noise from power end

Pump exhibits increased or higher than anticipated power consumption

Pump exhibits decreased or lower than anticipated power consumption

POSSIBLE CAUSES

POSSIBLE REMEDIES

rise.
2. A stiff cracked grease appearance.
3. A brown or bluish discoloration of
the bearing races.

lubricated bearings, be sure that there is space adjacent to the
bearing into which it can rid itself of excessive lubricant, otherwise
the bearing may overheat and fail prematurely.
3. Be sure the proper grade of lubricant is used.

Outer magnet assembly rubbing
bearing housing.

1. Check integrity of ball bearings.
2. Make sure drive shaft is not bent.
3. Make sure outer magnet assembly has not come unscrewed
due to incorrect motor rotation.