Upc/ean/jan supplemental redundancy, Transmit upc-a check digit – Datalogic Scanning QUICKSCAN QD 2300 User Manual

Page 110

Advertising
background image

Symbologies

104

QuickScan

®

L

UPC/EAN/JAN Supplemental Redundancy

With Autodiscriminate UPC/EAN/JAN Supplementals selected, this option adjusts the
number of times a bar code without supplementals is decoded before transmission. The
range is from two to twenty-two times. Five or above is recommended when decoding a
mix of UPC/EAN bar codes with and without supplementals, and the autodiscriminate
option is selected. The default is set at seven.
Scan the bar code below to set a decode redundancy value. Next, scan two numeric bar
codes in

Appendix E, Keypad

. Single digit numbers must have a leading zero. To correct

an error or change a selection, scan the CANCEL bar code located in

Appendix E, Key-

pad

.

Transmit UPC-A Check Digit

The check digit is the last character of the bar code used to verify the integrity of the data.
Scan the appropriate bar code below to transmit the bar code data with or without the
UPC-A check digit. It is always verified to guarantee the integrity of the data.

UPC/EAN/JAN Supplemental Redundancy

*

Transmit UPC-A Check Digit

Do Not Transmit UPC-A Check Digit

Advertising