Keyboard Wedge Interface

56

QuickScan

®

L

To connect the Keyboard Wedge interface Y-cable:

1. Turn off the host and unplug the keyboard connector.

2. Attach the modular connector of the Y-cable to the cable interface port on the scanner.

(See

Installing the Interface Cable on page 6

.)

3. Connect the round male DIN host connector of the Y-cable to the keyboard port on the

host device.

4. Connect the round female DIN keyboard connector of the Y-cable to the keyboard con-

nector.

5. If needed, attach the optional power supply to the connector in the middle of the Y-cable.

6. Ensure that all connections are secure.

7. Turn on the host system.

8. Select the Keyboard Wedge host type by scanning the appropriate bar code from

Key-

board Wedge Host Parameters on page 57

.

9. To modify any other parameter options, scan the appropriate bar codes in this chapter.

Keyboard Wedge Parameter Defaults

Table 9

lists the defaults for Keyboard Wedge host parameters. To change any option,

scan the appropriate bar code(s) in the Keyboard Wedge Host Parameters section begin-
ning on

page 57

.

NOTE

Interface cables vary depending on configuration. The connectors illustrated
in Figure 1 are examples only. The connectors may be different than those
illustrated, but the steps to connect the scanner remain the same.

NOTE

See

Appendix B, Standard Defaults

for all user preferences, hosts, symbolo-

gies, and miscellaneous default parameters.

Table 9. Keyboard Wedge Defaults

Parameter

Default

Page Number

Keyboard Wedge Host Parameters

Keyboard Wedge Host Type

IBM PC/AT& IBM PC Compatibles

1

57

Country Types (Country Codes)

North American

58

Ignore Unknown Characters

Send

59

Keystroke Delay

No Delay

60

Intra-Keystroke Delay

Disable

60