Datalogic Scanning QUICKSCAN QD 2300 User Manual

Page 40

Advertising
background image

RS-232

34

QuickScan

®

L

Table 6. Terminal Specific RS-232

Parameter

Standard

(Default)

ICL

Fujitsu

Wincor-

Nixdorf

Mode A

Wincor-

Nixdorf

Mode B/

OPOS

Olivetti

Omron

Transmit
Code ID

No

Yes

Yes

Yes

Yes

Yes

Yes

Data Transmis-
sion Format

Data as is

Data/Suffix

Data/Suffix

Data/Suffix

Data/Suffix

Prefix/Data/Suf-

fix

Data/Suffix

Suffix

CR/LF
(7013)

CR (1013)

CR (1013)

CR (1013)

CR (1013)

ETX (1002)

CR (1013)

Baud Rate

9600

9600

9600

9600

9600

9600

9600

Parity

None

Even

None

Odd

Odd

Even

None

Hardware Hand-
shaking

None

RTS/CTS

Option 3

None

RTS/CTS

Option 3

RTS/CTS

Option 3

None

None

Software Hand-
shaking

None

None

None

None

None

Ack/Nak

None

Serial Response
Time-out

2 Sec.

9.9 Sec.

2 Sec.

9.9 Sec.

9.9 Sec.

9.9 Sec.

9.9 Sec.

Stop Bit
Select

One

One

One

One

One

One

One

ASCII Format

8-Bit

8-Bit

8-Bit

8-Bit

8-Bit

7-Bit

8-Bit

Beep On
<BEL>

Disable

Disable

Disable

Disable

Disable

Disable

Disable

RTS Line
State

Low

High

Low

Low

Low = No data

to send

Low

High

Prefix

None

None

None

None

None

STX (1003)

None

*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes.

**If Nixdorf Mode B is scanned without the scanner connected to the proper host, it may appear unable to scan. If this happens, scan a
different RS-232 host type within 5 seconds of cycling power to the scanner.

Table 7. Terminal Specific Code ID Characters

ICL

Fujitsu

Wincor-

Nixdorf

Mode A

Wincor-

Nixdorf

Mode B/OPOS

Olivetti

Omron

UPC-A A

A

A

A

A

A

UPC-E E

E

C

C

C

E

EAN-8/JAN-8 FF

FF

B

B

B

FF

Advertising