Bottom valves hwv 205/1 - dn 80, Connecting lines, Bottom valves hwv 205/1-dn 80 connecting lines – Flowserve HV 205 User Manual

Page 15: Checking

Advertising
background image

15

Checking

– continued –

Bottom Valves HWV 205/1 - DN 80

Connecting Lines

Type of maintenance

Time interval

Activity

Check valve plug seal

When necessary,

during main

inspection at the latest

(every 4 yrs.)

Check valve head for leaks. If a leak is

detected replace valve plug seal as

described in section "Maintenance".

Replace valve plug seal

Main inspection

(every 4 yrs.)

Replace valve plug seal as described in

section "Maintenance".

Check actuating cylinder

When necessary,

during main

inspection at the latest

(every 4 yrs.)

Check connection between actuating

cylinder and body. If you detect an oil

leak replace the PTFE seal and the

O-ring as described in section

"Maintenance".

Check torque

of 50 Nm

When necessary,

during main

inspection at the latest

(every 4 yrs.)

Check the torques of the four hexagon-

head cap screws of the actuating cylinder

and, if necessary, retighten the screws to

a torque of 50 Nm.

Check torque

of 120 Nm

When necessary,

during main

inspection at the latest

(every 4 yrs.)

Check the torques of the six hexagon-

head cap screws of the body and, if

necessary, retighten the screws to a

torque of 120 Nm.

Replace piston seal

When necessary,

every 8

years at the latest

Replace piston seal as described in

section "Maintenance".

Type of maintenance

Time interval

Activity

Check tightness

When necessary,

during main

inspection at the

latest

(every 4 yrs.)

Make sure that no oil can escape

at connecting joints and T-type screwed

unions.

If necessary, retighten respective

connections.

31

31

D

14

22

13

Advertising