Maintenance

– continued –

Filling and venting of hydraulic indicating system

Open both bottom valves before filling the hydraulic indicating system.
Drawing see page 4

1.

Use the operating device

to open the bottom valves

.

2.

Loosen the venting plug

of the actuating cylinder

of the liquid phase in the

operating device

by half a turn.

3.

To fill the hydraulic indicating system connect an external oil hand pump with a
pressure gauge (measuring range: 0 -20 bar) to the filling connection

of the bottom

valve

for the liquid phase. Operate the pump until the oil leaves the venting plug

of the indicating cylinder

without any bubbles.

4.

Then fasten the venting plug

tightly.

5.

Continue to operate the external oil hand pump until the indicating piston

is

completely moved out and a pressure of approx. 10 to 20bar is indicated by the
pressure gauge.

6.

Finally remove the external oil hand pump from the filling connection

of the bottom

valve

and open the hydraulic system by loosening the tension rope

. The bottom

valve

closes automatically.

Follow the same steps when filling the bottom valve for the gas phase.

Performance test

Use both operating devices

for the performance test.

Drawings see pages 4 and 26

1.

To close the hydraulic system pull the tension rope

that closes the ball valve

of

the control unit

.

2.

Use the pump lever

of the hydraulic hand pump

in the operating device

and

perform approx. six strokes until you detect a slight resistance. The indicating
pistons

of both bottom valves

must now be in the open position and they must

be extended by approx. 46mm.

3.

During the hold time of approx. 2 hours the pressure must not decrease.

4.

Check all connections and screwed unions for oil leaks. If necessary re-tighten the
connections.

5.

Then re-open the hydraulic system by loosening the tension rope

.

6.

Both bottom valves

must close automatically and the indicating pistons

in the

operating devices

must be at the lower position.