Mounting bottom valve hwv 205 / 1 - dn 80, Mounting bottom valve hwv 205 /1- dn 80, Maintenance – Flowserve HV 205 User Manual

Page 20

Advertising
background image

20

Maintenance

– continued –

Mounting bottom valve HWV 205 / 1 - DN 80

Before mounting the bottom valve first attach the valve head from the outside to the
mounting flange.
Drawing see page 22

1.

Put the gasket

onto the valve head.

2.

Place valve head onto the mounting flange and tighten socket-head cap screws

and locking washer

with a torque of 120 Nm. Apply a commerically available

lubricant to the screws and tighten them in several steps in diagonally opposite pairs.

3.

Check spacing between bottom of valve plug

and seat flange

(reference

dimension 1 see page 22). For this purpose you can hold a try square to the bottom
of the valve head and read off the distance to the bottom of the valve plug. A distance
of 7± 1mm is required. If the reading exceeds this tolerance check the position of the
valve plug seal

of the valve plug

. If necessary push the valve plug

slightly

upwards.
Dirty seals or the incorrect position of the valve plug seal

may have caused the

problem. Should even after this examination the actual readings still exceed the
specified tolerances, please contact our Technical Service in your country, stating
the Gestra manufacturing number indicated on the name plate.

6

23

24

25

7

31

25

25

31

Attention

Check and, if necessary, clean sealing surfaces.

The specified torques must be strictly observed.

Advertising