Reworking seat flange, Maintenance – Flowserve HV 205 User Manual

Page 23

Advertising
background image

23

Maintenance

– continued –

Reworking seat flange

If the seating surface of the seat flange is slightly damaged you can remove and rework
the seat flange. For more details see drawing below.

To remove the seat flange please proceed as follows:
Drawing see page 19

1.

Remove body and the actuating cylinder

.

2.

Unscrew the 12 socket-head cap screws

and their associated locking washers

and remove the seat flange. Take out the gasket

.

3.

Unscrew the 6 stay bolts

together with the sleeves

out of the seat flange

.

Re-assembly in reverse order:
Drawing see page 19

1.

First push the sleeves

onto the 6 stay bolts

and screw them with a torque of 25

Nm to the seat flange

. Apply a commerically available lubricant to the screws and

tighten them.

2.

To mount the valve head follow the specified procedure (see page 19).

3.

Then put a new gasket

onto the seat flange

.

4.

Use the 12 socket-head cap screws

together with their locking washers

to

attach the valve head to the mounting flange. Tighten them with a torque of 120 Nm.
Apply a commerically available lubricant to the screws and tighten them in several
steps in diagonally opposite pairs.

D

23

24

6

4

5

7

5

4

7

6

7

23

24

Attention

The specified torques must be strictly observed.

(Ø 85 )

max.5 x 45°

Ra 0.8

Advertising