Emergency operation, Operation – Flowserve HV 205 User Manual

Page 31

Advertising
background image

31

Operation

– continued –

Emergency Operation

During emergency unloading the following actions will take place:



Opening of bottom valve



Closing of bottom valve

If both bottom valves

are to be opened, open first the bottom valve for the gas phase

and then the one for the liquid phase.
Drawing see page 4

1.

Unscrew the sealing plug

of the bottom valve

located in the bottom of the

actuating cylinder

. A small amount of oil might escape.

Put the sealing plug

in the operating device

.

2.

Unscrew one or two of the required screws for sealing off the opening for emergency
unloading

from one of the operating devices

and apply a smear of commercially

available lubricant to them.
They are screwed one below the other to the back of the operating device

.

4.

Screw the sealing-off screw

into the thread at the bottom of the actuating

cylinder

in order to open the bottom valve

.

5.

Open the lateral shut-off valves

to start the loading/unloading process.

A

V

A

D

V

B

Y

B

B

Y

D

A

E

Warning

Use the emergency operation of the bottom valves only if both hydraulic
hand pumps have failed or, for any other reason, there is not enough
pressure for opening one or both bottom valves.

In case of emergency operation the rapid-action closing of the bottom
valve is not possible.

Advertising