FSR CB-12 / CB-12P ELECTRICAL HOOKUP INSTRUCTIONS User Manual

Page 4

Advertising
background image

Page 4 of 4

43185 LIT1417

10) Attach the looped end of ground bond wire to the chassis ground screw as shown in

figure 6 and tighten to specifications.

Figure 6

11) Connect incoming branch circuit 14 AWG copper line and neutral conductors to

remaining push wire connection ports of duplex receptacle as shown in Figure 5. Note
applicable strip length and polarity.

12) Reinstall the electrical box cover, taking care not to trap wires between the cover and

the adjoining metal chassis. Reinstall and tighten the cover retaining screws removed in
step 1.

13) Restore branch circuit power and test the polarity of all receptacles.


Advertising