Model 226-700
The mounting and wiring instructions for the Model 226-700 Telephone are as follows:
1. Remove the eight security screws
from the front panel. Remove the
front panel and set aside.
2. There are eight mounting holes in
the back of the enclosure in two 4-
hole patterns. Determine which hole
pattern will be used for mounting.
See Figure 5.
For best results, use the
7.875
4.0-inch hole pattern for
mounting to a wall (outside
pattern).
Use the 5.25 4.0-inch hole
pattern when using the Model
232-001 Pole Mounting Kit
(inside pattern).
3. Insert four hole plugs (provided) in
the unused holes.
4. Position the enclosure on the mounting surface and
secure it with four fasteners.
The holes in the telephone enclosure accept 3/8-inch
screws or bolts.
The Model 232-001 Pole Mounting Kit includes four
3/8-16
1-inch shoulder bolts with Teflon seal
washers.
NOTE
Use only the round head, hexagon
head, or pan head screws that are provided.
Do not use screws designed to be countersunk for
mounting the enclosure.
5. Install a conduit fitting in one of the 1/2-inch NPT
conduit entrances provided at both the top and bottom of
the unit, and insert the conduit into the fitting. (The
bottom location is preferred. See Figure 4.) Plug the
unused access hole using the 3/8-inch Allen drive plug
provided.
N
OTE
: Use silicone sealant or equivalent around and
inside all conduit entries.
Figure 3. Model 226-700 VoIP Telephone with spring loaded