Pub. 42004-600L2C

Model 12580-001 Amplifier Distribution/Monitor Module

Page: 7 of 17

f:\standard ioms - current release\42004 instr. manuals\42004-600l2c.doc
10/11

Data Communication Line

Terminal block, TB21 is provided to enable the RS-485 signal to be daisy-chained to additional
Snaptrack™ modules. The pinout for the data communications line is shown in Table 4.

Table 4. Data Communications Line - TB21 Pinout

Pin

No.

Function

Description

1

485

+

Daisy-chains the positive leg of the RS-485 interface to other Snaptrack

™ modules

(I/O)

2

485

Daisy-chains the negative leg of the RS-485 interface to other Snaptrack

™ modules

(I/O)

N

OTE

: The conductors terminated on this terminal block should be a twisted pair.

Central Amplifier Audio Distribution

Terminal blocks TB2, TB5, TB8, TB11, TB14, and TB17are provided to connect audio from the AZI to
the six central amplifier inputs. The audio signals are differential, so a 2-connductor cable is required for
each input. An additional termination point (EGND) has been provided for an earth ground connection.
The pinout for TB2, TB5, TB8, TB11, TB14, and TB17 is shown in Table 5.

Table 5. Central Amplifier Audio Distribution - TB2, TB5, TB8, TB11, TB14, and TB17 Pinout

Pin

No.

Function

Description

1

AMP

L1

Connects one leg of audio to a central amplifier’s input (output)

2

AMP

L2

Connects the other leg of audio to a central amplifier’s input (output)

3

AMP

EGND Connects earth ground to a central amplifier (output)

N

OTE

: For optimum audio quality, the conductors terminated on pins 1 and 2 of these terminal blocks

should be twisted pairs.