Gasboy 9820Q Series User Manual

Installation instructions, 9820q totalizer kit

Advertising
background image

031907

Rev. 12/03/03

INSTALLATION INSTRUCTIONS, 9820Q TOTALIZER KIT


This instruction sheet details installation of the 9820Q totalizer kit. Be sure to read and obey all warnings and safeguards
as outlined in the enclosed Warnings and Safeguards Sheet. Kit contents are as follows:

Item P/N

Description

1

015113

Bracket, 9 dig. tot. mount, Qty 1

2

039070

Nut, #8-32 Hex Keps, Qty 2

3

039824

Odometer, 9-dig. CCW, Gallon, Qty 1

039825

Odometer, 9-dig. CCW, Liter, Qty 1

4 017366 Cable

Assy., Drive, 9-dig. tot. , Qty 1

5

043220

Pin, Spirol, 1/16” x 1/2” , Qty 1

Item P/N

Description

6

C04039

Screw, #6-32 x 1/2” Phil. Pan Hd, Qty 2

7

042290

Pin, Cotter, 3/64” x 1/2” , Qty 1

8

C08126

Cable Tie, Qty 1

9

022577

Totalizer Bracket, Qty. 1

10

053919

Screw, Qty. 2

031907 Installation

Instructions


1. Turn off and lock out all power to the system.

2. Remove sheet metal cover from the unit.

3. Install Totalizer Bracket (9) to the frame with two 1/4-20 x 1/2

Taptite screws (10). (See Figure 1.)


4. Install the Drive Cable Assembly (4) to the Totalizer/Odometer

(3) using the Spirol Pin (5) NOTE: Cable end fitting with smaller
mounting hole goes to totalizer
. (See Figure 2, Detail B.)


5. Install assembled Drive Cable Assembly (4) with the

Odometer/Totalizer (3) to the Totalizer Bracket mount (1), using
the two 6-32 screws (6). Then, use the two 8-32 hex keps nuts
(2) to attach this completed assembly to the Totalizer Bracket (9)
that was installed in Step 3. (See Figure 2, Detail B.)


6. Route the Drive Cable Assembly under the meter and up to the

flange of the frame. Use the cable tie (8) to secure the drive
cable in place where a hole is located in the frame. (See Figure
1.)


7. Install the loose end of the

Drive Cable Assembly to
the Gear Train Assembly
under the pulser housing
using the Cotter Pin (7).
(See Figure 1, Detail A.)


8. Restore power to the unit

and check for proper
operation of the totalizer.

Advertising