INSTALLATION INSTRUCTIONS FOR HIGH HOSE RETRIEVER

FOR MODEL 9800A/2600A WITH VAPOR RECOVERY

This instruction sheet covers the installation of the Model 9800A/2600A Balanced System Vapor Recovery Kit.
If you ordered a vapor recovery kit, 032045, you should have received the following:

Item

Part No.

Description

1

030314

HHR Reel, Premier VR

2

063838

Support Bar, HHR 9800

3

017930

Caplug, 1-1/2 Sq. Tube

4

051956

Screw, 5/16-18x2, SS

5

068079

Washer, 5/16, SS

6

068874

Washer, Std Spring Lock, 5/16, SS

7

056927

Spacer, 1-1/2 x 1-1/4 dia.

8

013250

Bolt, 5/16 Mach Anchor, HHR

9

047219

Plug Button, 7/8

10

051957

Screw, 5/16-18 x 2-1/2, SS

11

064560

Swivel, Hose, 3/4, #36S

12

038502

Nozzle, Emco VR A4005 Stg II

Item

Part No.

Description

13

030301

Hose, Goodyear, Premier Coax, 7’6”

14

066817

Splitter, Emco, 4041-002

15

030407

Hose, 3/4" x 1’6” HW UL

16

017270

Bushing 3/4 x 1”

17

044007

Breakaway Coupling, Coax, Emco,
#A4019-1

18

030303

Hose, Goodyear, Premier Coax 4’6”

19

003336

Boot, Nozzle, VR

20

003719

Hook, Nozzle, VR

21

032024

Installation Instructions (this sheet)

22

035282

Warnings and Safeguards Sheet

1.

Read all the instructions before beginning. A separate instruction sheet is packed with the Emco Wheaton
splitter manifold, which is required for mounting this component. Also read and follow all precautions
regarding remote dispensers and pumps on the Warnings and Safeguards sheet, 035282 (included in this
kit).

2.

Turn off power to the dispenser at the breaker and activate emergency shutoff valve.

3.

Item 14 must be mounted to the unit using the template and instructions furnished by Emco Wheaton.

4.

Item 7 mounts between HHR post and side panel.

5.

Item 8 requires a 5/8” diameter x 1-3/4 deep hole in the island.

6.

Item 16 is required for units with 1” discharge assembly.

7.

Item 17 must be installed approximately 12” downstream of hose retractor clamp.

8.

To reduce the risk of accidental dispensing of fuel, turn off all power.

9.

Use UL-Listed gasoline resisting compound on all joints of gasoline handling fittings. Sealing compound
must also be resistant to gasohol (ethanol and methanol). Do not use Teflon pipe sealing tape. Use
gasoline resistant pipe compound on all male threads only.

10. Tighten all hardware. Plug hole in post with Item 9.

Mounting of Nozzle Boot and Nozzle Hook

1.

Remove the 4 screws from the existing nozzle boot and remove nozzle boot. Add new nozzle boot (item
19) with existing screws.

2.

Remove hardware from existing nozzle hook.

3.

Remove two plugs from lower mounting holes of side panel and plug upper holes.

4.

Install new nozzle hook (Item 20) in lower holes with existing hardware.