Gasboy 215A User Manual

Gasboy Hardware

Advertising
background image

032138 Rev 1212

Page 1

INSTALLATION INSTRUCTIONS FOR

MODEL 215A FRONT LOAD VAPOR RECOVERY KIT 032137

This instruction sheet covers the instruction of the Model 215A Front Load Balanced System Vapor Recovery
Kit. If you are installing another manufacturer’s vapor recovery system, you may need to modify the nozzle boot
using the Modify Nozzle Boot instruction below. Vapor Recovery Kit, 032137 contains the following:

Item

Part No.

Description

1

032671

HHR Kit, Clamp and Reel, VR (GY
Prem)

2

063816

Support Bar, HHR

3

017930

Caplug-1-1/2 Sq. Tube

4

051956

Screw, 5/16-18x2, SS

5

068079

Washer, 5/16, SS

6

068874

Washer, Lock, Std Spring, 5/16, SS

7

056924

Spacer, HHR

8

013250

Bolt, 5/16 Mach Anchor HHR

9

047219

Plug Button, 7/8

10

038605

Nut, 5/16-18 Hex Keps

Item

Part No.

Description

11

064560

Swivel, Hose, 3/4, #36S

12

038502

Nozzle, Emco VR A4005 Stg II

13

030301

Hose, GY Max Prem, 7.5’

14

066817

Splitter, Emco, 4041-02

15

030407

Hose, 3/4” HW UL 1.5

16

017270

Bushing, 3/4 x 1

17

044007

Breakaway Coupling, Coax
OPW66CL0250

18

030303

Hose, GY Max Prem 4.5’

19

032138

Instructions (this sheet)

20

035282

Warnings and Safeguards Sheet

IMPORTANT:

Always use a UL-classified gas and oil resistant pipe compound on all male pipe threads when assembling

these components. All references to pipe compound in these instructions imply UL-classified pipe compound.

1. Read all instructions before beginning. A separate instruction sheet is packed with the EMCO Wheaton

splitter manifold, which is required for mounting this component. Also read and follow all precautions
regarding remote dispensers and pumps on the Warning and Safeguards Sheet, 035282, included in this kit.

2. Turn off power to the dispenser at the breaker and activate emergency shutoff valve.

3. Mount the splitter per the EMCO Wheaton instructions.

Assemble Product Jumper Hose

Assemble 3/4” x 1” bushing (017270) to dispenser outlet. Assemble 3/4” swivel (064560) to one end of the 3/4”
jumper hose (030407). Assemble fixed end of jumper hose to bushing on dispensing outlet, and the swivel end
at the splitter port labeled FUEL.

Mount Hose Retriever

1. Assemble clamp & reel assembly (Item 1) to support post (Item 2) with items 4, 5 & 6.

2. Install reel and post assembly to side of unit with Items 4, 5, 6, 7, & 10, and leave loose. Item 7 mounts

between post and side panel.

3. Making sure the support post is plumb, mark and drill a 5/8” dia. x 1-3/4” deep hole in island. Install anchor

bolt (item 8) into island surface. Install items 4, 5, and 6.

4. Tighten all hardware. Plug hole in post with item 9.

Modify Nozzle Boot

If using a long spout vapor-recovery nozzle, it may be necessary to remove the nozzle restraint bracket and the
lock.

Advertising