Power supply, Powermax1000, Specifications 2-2 – Hypertherm Powermax1000 Service Manual User Manual

Page 29: Service manual

Advertising
background image

SPECIFICATIONS

2-2

powermax1000

Service Manual

1

Power supply

Rated open circuit voltage (U

0

)

300 VDC

Output characteristic*

Drooping

*Defined as a plot of output voltage

versus output current

Rated output current (I

2

)

20A – 60A

Hypertherm standard rated output

140 VDC

voltage (U

2

)

Duty cycle (X*) at 104°F (40°C) at

U

1

– Volts AC rms

X

rated conditions (U

1

, I

1

, U

2

, I

2

)

200-208 VAC 1PH

40%

230-240 VAC 1PH

50%

*X = T

on

/T

base

,

480 VAC 1PH

50%

T

on

= time, minutes

200-208 VAC 3PH

40%

T

base

= 10 minutes

230-240 VAC 3PH

50%

380/400/415 VAC 3PH

50%

480 VAC 3PH

50%

600 VAC 3PH

50%

Operating temperature

14° to 104° F (-10° to 40° C)

Rated AC phases (PH) and line frequency (Hz)

PH

Hz

Standard model

1-3

50-60

CE model

3

50-60

Rated input voltage (U

1

), rated input

U

1

– Volts AC rms

I

1

-Amps rms

I

1

eff

current (I

1

) and I

1

eff* at rated output

200-208 VAC 1PH

50

32

U

2

and I

2

– cutting only.

230-240 VAC 1PH

44

31

480 VAC 1PH

22

15.5

200-208 VAC 3PH

30

19

*I

1

eff = (I

1

)

X used to determine

230-240 VAC 3PH

26

18

rating of power cord.

380/400/415 VAC 3PH

15

10.5

480 VAC 3PH

12

8.5

600 VAC 3PH

11

8

Power factor

U

1

– Volts AC rms

Harmonic power factor

Displacement
power factor

200-208 VAC 1PH

0.99

0.99

230-240 VAC 1PH

0.99

0.99

480 VAC 1PH

0.91

0.99

200-208 VAC 3PH

0.94

0.99

230-240 VAC 3PH

0.94

0.99

380/400/415 VAC 3PH

0.94

0.99

480 VAC 3PH

0.94

0.99

600 VAC 3PH

0.80

0.99

R

sce

– short circuit ratio—CE model only

U

1

– Volts AC rms, 3PH

R

sce

400 VAC

153

230 VAC

97

This equipment conforms to IEC 61000-3-12, provided that

R

sce min

= 153 at 400 VAC 3PH and 97 at 230 VAC 3PH.

IP code—degree of protection provided by

IP23CS*

enclosure

IP – “International Protection”
2 – No ingress foreign objects

>

=12.5mm (0.5 in)

3 – No harmful ingress spraying water
C – AC line circuits protected against ingress of tool

>

=2.5 mm

dia. x 100 mm long (0.1 in x 4.0 in)

S – fan stationary during water test

*

WARNING: DO NOT OPERATE IN THE RAIN

Toppling, Tilting (with or without wheel kit)

Up to 15° incline

.

Gas type

Air

Nitrogen

Gas quality

Clean, moisture-free, oil-free

Gas inlet pressure and flow

90 psig (6.1 bar) 400 scfh/6.7 scfm (189 l/min)