Control board leds, Powermax1000, Maintenance 3-18 – Hypertherm Powermax1000 Service Manual User Manual

Page 51: Service manual, Diagnostic leds

Advertising
background image

MAINTENANCE

3-18

powermax1000

Service Manual

1

Control board LEDs

If the red Fault LED illuminates, no yellow LEDs are illuminated, and the green AC and Gas pressure LEDs remain
illuminated, check the LEDs on the rear of the control board (PCB3).

70

50

4560

55

65

75

80

85

START

START

XFR

SDF

START

IF

START

TSO

START

SP

.

.

.

.

Diagnostic LEDS

START

XFR

SDF

IF

TSO

SP

START SIGNAL VALID

TRANSFER

SELF DIAGNOSTICS FAILURE

INVERTER INTERLOCK

(Blinking at 1 sec. rate)

(Visible for 10 sec. after event)

TORCH STUCK OPEN

(Visible for 10 sec. after event)

SPARE

P1

UP

MID

DOWN

CPA

NORMAL

GOUGE

CURRENT

GAS

STATUS