T60 hand torch connector pinouts and assembly
WHITE
RED
J18
VIOLET
ORANGE
BLUE
ELECTRODE
NOZZLE
CAP
START
KEY
NOTE: PIN 6 IS THE KEYING FEATURE FOR 60A AND 80A TORCHES
X
1
2
3
4
5
6
7
8
9
10
11
12
Blue rubber seal
White wires (plunger)
Red dot
Pin 1
Pin 10 violet wire (trigger)
Orange wire (cap sensor/trigger)
Pin 12 blue wire (cap sensor)
Pin 3
Not used
Red wire (nozzle)
Right
handle
Left
handle
Torch
body
Spring
Trigger
Screws (5)