Controls and indicators, Indicator leds, Powermax1000 – Hypertherm Powermax1000 Service Manual User Manual

Page 36: Maintenance, Service manual 3-3

Advertising
background image

MAINTENANCE

1

Controls and indicators

6.0
BAR

5.0

4.0

PSI

80

70

5060

60

40

AMPS

80

25

V

AC

+

_

Current
(amps)
adjustment
knob

Mode switch

Indicator
LEDs

Pressure
gauge

Pressure
regulator

ON (I) / OFF (O)
switch (S1)

Green power ON LED
When illuminated, indicates that power is applied to the system and the power switch is ON (I).
Note: The LED should illuminate when the power is ON (|).

Gas pressure LED
Yellow:

When flashing, indicates that the gas pressure is below 60 psig (4.1 bar) for cutting, or 40 psig
(2.8 bar) for gouging.

Green: When illuminated, indicates acceptable gas pressure for torch operation.

Note: The LED should illuminate when the power is ON (|).

Yellow torch cap LED

When illuminated, indicates that the retaining cap is loose or not installed.
Note: Turn the power OFF, correct this fault condition, then turn ON the power to extinguish the LED.

Yellow temp LED

When illuminated, indicates that the power supply’s temperature is too hot.

Red fault LED

When illuminated, indicates that a fault condition exists, which prevents system operation.

Yellow low line voltage LED

When illuminated, indicates that line voltage is below 170 VAC or above 680 VAC. On CE units, it can
also indicate a missing phase.