Electrical schematics, Pcb3, Control bd – Hypertherm Powermax1000 Service Manual User Manual

Page 92

Advertising
background image

6-5

3

U22

U23

(VISIBLE FOR 10 SEC. AFTER EVENT)
TORCH STUCK OPEN

40 POSITION RIBBON CABLE

(VISIBLE FOR 10 SEC. AFTER EVENT)

129683

WIRE GROUP

123607
123603
003206
NA
041667

POWER SWITCH (S1)

MACHINE INTERFACE CABLE

POWER BD (PCB2)

FILTER (PCB1)

CONTROL BD (PCB3)

123603

041660

003206

041667

041663

041707

80 AMP UNIT

1.41 X Vac
129652

200-600vac

750

INPUT VOLTAGE

Vbus (Vac>541vac)
CORD

Vbus (Vac<540vac)

750
NA
129653

70

50

STATUS

GAS

45

60

55

65

75

80

85

TSO

SP

SPARE

0.10uF
009994

33

J4

108171

39
40

37
38

35
36

34

008924

0.01uF

100VDC

009990

TP1

IFB

ITF

VACR

C41

50V

R50

100

009073

C52

32

30
31

28
29

26
27

22

25

24

23

21

19
20

009994

VBUS

+5

C1

0.10uF

50V

+5

/IOC

009115

10

R4

R3

10

009115

TEMP
PCB4

SENSOR BD

HEATSINK

SENSOR

SA

PRESSURE

1

3 2

B

Y

J5

R

TEMP

SENSOR IN

XFMR

T2

J21

2

B

R

1

3

B

2

X

SA

FAN

Y

1

J2

1

R

2

B

J1

GAS SOLENOID

SA

B

3 2

R

1

J20

X

+24

10

R117

10

009115

009115

R116

+5

+5

DIAGNOSTIC LED'S

START SIGNAL VALID

INVERTER INTERLOCK

(BLINKING @ 1 SEC. RATE)

SELF DIAGNOSTICS FAILURE

INSTALL JUMPER 108056 CE UNITS ONLY

PCB3

CPA
NORMAL
GOUGE

CURRENT

DOWN

MID

UP

CONTROL BD

P1

XFR

SDF

IF

TRANSFER

START

(PE)

BRN

GRN/YEL

BLK
BLU

CE UNIT

CORD

S1

J1

AUX

FILTER

PCB1 J2

(PE)

RED
GRN

AUX

DOMESTIC UNIT

BLK
WHT

S1

CORD

3

10

7

11

18

17

15
16

13
14

12

10

8
9

6
7

4
5

D8

C18
50V

0.10uF
009994

5.1V

1N5231B
109109

OUTB

R22

R8

009883

1/2W

2.21K

009414

499

009036

OUTA

8

+V

7B

-V

7C

9

R7

2.0K

3

1

109223

55V

IRLZ44N
0.022ohm

C13

0.10uF

50V

009994

2

/MM

+24

Q1

2
3

1

J3

B

Y

1

+24

PE

2

MTG-4

1

3

2

4

5

6

3B 3C

4B 4C

6B 6C

5C

5B

13

12

11

1C

1B

2B 2C

16

14

15

042188

ULN2003A

U1

/PREFLOW

/SSR

/PA

t

60V 0.20A

RT7
109024

BRIDGE

~

-

~

~

D24

INPUT

+

GND

CONTROL

-6

COMT
18REG

18T

COMINV

18INV

FLYBACK

SUPPLY

POWER

SYSTEM

T1

18PA

COMPA

+5

+10

+24

PE

CKT

PFC

CONTROL

POWER BD PCB2

SOFT START

K1

VacR

I

Vbus

1

3

2

J8

PFC

IGBT

Q7

C94

+

2

1

J6

3

2

Vbus

OR J10

J9

PFC CHOKE

C98

+

J7

1

POWER

TRANSFORMER

20 OHM

YEL

J13

YEL

P2

50W

BRN

BRN

INVERTER

IGBT Q6

T2

ITF

SENSOR

J19

/MM

+24

4

3

COMT

18T

2

1

12

10

11

INTERFACE

GND

CHASSIS

BLK

GRN/YEL

YEL

12

13

14

MACHINE

START

WHT
RED

3

4

CAP

1

COMT

8
9

6
7

4
5

2
3

J18

J17

CKT

J14

WHT

RED

NOZZLE

ELECTRODE

WORK LEAD

TRANSFER

IFB

CURRENT

SENSOR

FEEDBACK

J12

IGBT

PILOT ARC

NC

INDUCTOR

OUTPUT

B

R

OUTPUT

DIODES

J11

7.5 ohm

100W

NA

1.41 X Vac

750

750
NA

60 AMP UNIT

087000(DOMESTIC)

087007(CE)

083169(DOMESTIC)

083170(CE)

1/3PH

230-400vac
3PH

200-600vac
1/3 PH

230-400vac
3PH

TEMP SENSOR BD (PCB4)

041723

041723

TIMING DIAGRAM

013341

013341

129652

129726

129732
123603

123603

005257

005257

041746

041746

041709

041710

041713

041713

013341

013341

041773

LOCKOUT

VIO

ORG

BLUE

129739

NOTES:

1. PIN 6 IS KEYING FEATURE ON 60A

2. PIN 9 IS LOCKOUT FEATURE

6

5

+
-

+24

24VDC @100MA MAX

TOLERANCES ARE:

UNLESS OTHERWISE SPECIFIED:

2 PL DECIMAL ±.01

FRACTIONS ±1/64

ANGULAR ±.5∞

DIMENSIONS ARE IN INCHES.

3 PL DECIMAL ±.005

PART MUST BE FREE OF BURRS AND SHARP

EDGES. BREAK SHARP EDGES IF NECESSARY

WITH CHAMFER OR RADIUS .015 MAX.

PURPOSES WITHOUT PERMISSION

FOR MANUFACTURING OR FABRICATION

FROM HYPERTHERM, INC.

THIS DRAWING AND ALL INFORMATION

PROPRIETARY AND MAY NOT BE USED

CONTAINED THEREON IS CONSIDERED

MATERIAL

1=1

1 OF 1

SCALE

Box-5010 Hanover, NH 03755-5010 603/643-3441

SHEET

8

7

6

3

5

4

2

1

A

B

C

D

8

7

6

3

5

4

2

1

A

B

C

D

C