Hypertherm igbt tester, Indicator leds and device tests, Igbt test preparation – Hypertherm Powermax1000 Service Manual User Manual

Page 42: Powermax1000, Maintenance, Service manual 3-9 hypertherm igbt tester

Advertising
background image

MAINTENANCE

1

powermax1000

Service Manual

3-9

Hypertherm IGBT tester

Use the Hypertherm IGBT tester (part number 128883) as described in the following sections or assemble your
own IGBT tester from the schematic diagram shown in

IGBT tester schematic and use it to test the IGBTs.

128884

Red “fail” LED
When illuminated, this LED indicates that the IGBT failed the test for an open IGBT when the switch
is pressed to the right or for a shorted IGBT when the switch is pressed to the left.

Green “pass” LED
When illuminated, this LED indicates that the IGBT passed the test for an open IGBT when the
switch is pressed to the right or for a shorted IGBT when the switch is pressed to the left.

Red “low battery” LED
When illuminated, this LED indicates that the remaining voltage in the battery is insufficient to power
the test circuitry. Replace the battery.

Note:

The Hypertherm IGBT tester requires a minimum of 8V to properly power its circuitry.

Indicator LEDs and device tests

Pass LED

(green)

Collector

(red)

Circuit
diagram

Fail LED

(red)

Test for

shorted IGBT

Low battery
LED (red)

Test for
open IGBT

Rocker
switch

Gate

(yellow)

Emitter

(black)

IGBT test preparation

Before testing with the Hypertherm IGBT tester, connect the colored leads to the IGBT as shown below.

Before an IGBT can be tested, it must be electrically isolated from all circuits. If the IGBT is installed in a power
supply, remove the power board and any lead connections before testing.

Advertising