Test 1 — voltage input, Powermax1000, Maintenance – Hypertherm Powermax1000 Service Manual User Manual

Page 52: Service manual 3-19 test 1 – voltage input

Advertising
background image

MAINTENANCE

1

powermax1000

Service Manual

3-19

Test 1 – voltage input

• Check the line voltage to the top of the power switch (S1).

• Check the input voltage to the input diode bridge.

• The AC voltage between any 2 input wires should equal the line voltage.

• If there is proper voltage to the power switch and low voltage to the input diode, replace the power switch.

• For CE systems, check the voltage at the CE filter. If there is proper voltage to the CE filter and low

voltage to the input diode, replace the CE filter.

• Check the output voltage of the input diode bridge.

• Output VDC = Line Voltage x 1.414 VDC.

Note:

All values can be ±15%.

= Line voltage*

= Line voltage

= Line voltage*

Input diode bridge

Power switch (S1)

* Single phase

Line voltage x 1.414

Ground (PE)

L1 (U)

L2 (V)

L3 (W)

Standard unit

CE unit

L1

Black

Black (U)

L2

White

Blue (V)

L3

Red

Brown (W)

PE

Green

Green/Yellow

Advertising