Test 2 — voltage balance, Powermax1000 – Hypertherm Powermax1000 Service Manual User Manual

Page 53

Advertising
background image

MAINTENANCE

3-20

powermax1000

Service Manual

1

Test 2 – voltage balance

Test to check the balance of the bus voltage, the power-factor circuit, and the soft-start circuit.

• Verify the system’s serial number. Serial numbers lower than 1000-016236 have a different power board

from systems with serial numbers higher than 1000-016236.

• Remove screws from capacitors C94 and C98 before measuring the resistors listed below.

• Check the voltage across the inverter IGBT (Q6).

• Check the voltage across the capacitors (C94, C98) before and during torch operation.

• Voltage across both capacitors should be 375 VDC.

On systems with serial numbers below 1000-016236, if the capacitors are not balanced at 375 VDC, install the
RCD resistor kit (PN 128963). For systems with higher serial numbers, replace the power board.

Note:

All values can be ±15%.

750 VDC

375 VDC

375 VDC

C94

375 VDC

C98

375 VDC

Bus-bleed and soft-start
resistors for serial numbers
above 1000-016236.

R124 = 75k

R125 = 75k

R126 = 75k

R127 = 75k

80

C100

Bus-bleed and soft-start
resistors for serial numbers
below 1000-016236.

R118 = 3

R119 = 25k

R120 = 25k

Note: Bulk capacitors must be
out of circuit.
R126 = 20.8k

R120 = 21.2k

R125 = 21.0k

R127 = 21.2k

R124 = 24.1k
R119 = 24.1k

Inverter IGBT (Q6)