Inclination sensor JN

13

Index

Sub-

index

Name (parameter)

Type

Default value

Save

1803h

Transmit PDO3 communication parameter
0

Highest supported sub-index

ro

u8

5

1

COB ID

ro

u32

480h + node ID

2

Type of transmission

(synchronous/asynchronous)

rw

u8

1

3

Disable time between

two TPDO messages

(multiple of 100 µs)

rw

u16

0

5

Interval time for cycl. transmission

(multiple of 1 ms,

0 deactivated)

rw

u16

10

1A00h

Transmit PDO0 mapping parameter (fixed mapping)
0

Highest supported sub-index

ro

u8

2

Yes

1

Inclination value longitudinal

(X axis)

ro

u32

60100010h

2

Inclination value lateral

(Y axis)

ro

u32

60200010h

1A01h

Transmit PDO1 mapping parameters (fixed mapping)
0

Highest supported sub-index

ro

u8

2

Yes

1

Inclination value longitudinal

(X axis)

ro

u32

61100020h

2

Inclination value lateral

(Y axis)

ro

u32

61200020h

1A02h

Transmit PDO2 mapping parameters (fixed mapping)
0

Highest supported sub-index

ro

u8

2

Yes

1

Veff

ro

u32

5C100020h

2

aPeak

ro

u32

5C110020h

1A03h

Transmit PDO3 mapping parameters (fixed mapping)
0

Highest supported sub-index

ro

u8

3

Yes

1

aVector X axis

ro

u32

5D100020h

2

aVector Y axis

ro

u32

5D110020h

3

aVector Z axis

ro

u32

5D120020h

1F80h

NMT start-up
0

Slave only

rw

2

Start-up capable device

NMT start command

rw

8

Start-up capable device

autostart feature only

rw