26

10 Vibration measurement

10.1 Measurement mode (SDO index 2047h)
The JN2100 sensor can be operated in four different measurement modes:

● Angle measurement (SDO index 2047h = 0)

● Vibration measurement (Veff & aPeak) (SDO index 2047h = 1)

● Raw acceleration (AC measurement / dynamic) (SDO index 2047h=2)

● Raw acceleration (DC measurement / static) (SDO index 2047h=3) →

automatic selection of ±2 g

The table shows which settings can be combined:

OD index 0x204A

OD index 0x2047

Measuring range

Angle

measurement

Veff & aPeak

Raw acceleration
AC measurement

Raw acceleration
DC measurement

± 2g

X

X

X

X

± 4g

O

X

X

O

± 8g

O

X

X

O

(X → possible; O → not possible)

The angle measurement and raw acceleration (DC measurement) is only possible at ± 2 g.

10.1.1 Vibration measurement (Veff & aPeak) (SDO index 2047 = 1)
If the vibration measurement is active, the sensor provides two different

characteristic values.
The first characteristic value (SDO index 5C10h) provides the vibration velocity

(v effective [1/10 mm/s]) and the second characteristic value (SDO index 5C11h)

the maximum acceleration (a peak [mg]).

Axis selection is only possible in this option.

10.1.2 Raw acceleration measurement (AC) (SDO index 2047h = 2)
In this mode the values of the 3 axes (X/Y/Z) are provided with sign. The output

values of all axes is 0 mg.
This option is possible up to a measurement range of ± 8 g.
10.1.3 Raw acceleration measurement (DC) (SDO index 2047h = 3)
When this option is active, the values of the 3 axes (X/Y/Z) are provided with sign.
The difference to the previous option is that now measurement is made statically

at ± 2 g and in horizontal position of the sensor the earth's gravitational force acts

on the Z axis (9.81 m/s² → 1000 mg).