Inclination sensor JN

25

9.8 Temperature of the measuring cell (SDO index 4080h)
The temperature of the measuring cell is determined every 200 ms and updated in

the object directory. It can be read via SDO access to the object directory (in every

device state) and via TPDO. The signed 32-bit value (two's complement) indicates

the temperature in °C.
9.9 Inclination values longitudinal and lateral (SDO index 6010h and

SDO index 6020h)
The current angle values of the inclination axes can be accessed via SDO access

to the object directory (in every device state) and via TPDO. The conversion of the

100-fold, signed 16-bit inclination value (two's complement) is as follows:
Value of the SDO index 6010h = -2370, thus the angle is -2370 / 100 = -23.70°
9.10 Programming key (SDO index 3000h)
The sensor can convert the parameter setting unambiguously into a Base64-

coded key. By means of this key sensors with the same parameter setting can be

duplicated in an easy way.
The programming key can be read from and written to SDO index 3000h sub-index

0. To ensure that only valid keys are accepted by the firmware a 2-byte checksum

(CRC) is calculated and added to the end of the key.
The following parameters are coded by the key

Parameter

SDO index

SDO sub-index

Node ID

0x2000

0x00

Baud rate

0x2001

0x00

Quadrant correction

0x2040

0x00

Heating on

0x2041

0x00

Teach index

0x2042

0x00

FIR filter angle

0x2043

0x00

Angle calculation

0x2044

0x00

CAN 120 Ohm resistor

0x2045

0x00

Set zero point

0x2046

0x00

Output value

0x2047

0x00

Axis selection for Veff & aPeak

0x2048

0x00

FIR filter for vibration measurement

0x2049

0x00

Measuring range vibration measurement

0x204A

0x00

Resolution

0x6000

0x00