13 maintenance, repair and disposal, 14 approvals/standards, 15 factory setting – ifm electronic JN2100 v.2.2.0 User Manual

Page 32

Advertising
background image

Inclination sensor JN

32

13 Maintenance, repair and disposal

The unit is maintenance-free.

► Dispose of the device in accordance with the national environmental

regulations.

14 Approvals/standards

The CE declarations of conformity and approvals can be found at:

www.ifm.com → Data sheet search → JN2100

15 Factory setting

SDO

index

Sub-

index

Type

Value

Delivery

0x2000

0x0

u8

Node ID

10

0x2001

0x0

u16

Baud rate

125 Kbits

0x2040

0x0

u8

Flag for quadrant correction

2: corresponds to "0° ... 360°"

0x2041

0x0

u8

Flag for heating

1: corresponds to "heating on"

0x2042

0x0

u8

Index teach value of the X/Y/Z axes

2: corresponds to "absolute

measurement"

0x2043

0x0

u8

FIR filter step angle

2: corresponds to "FIR lowpass

5Hz"

0x2044

0x0

u8

Angle calculation

0: corresponds to "perpendicular"

0x2045

0x0

u8

CAN 120 Ω terminating resistor

1: corresponds to "activated"

0x2046

0x0

u8

Set zero point of the X/Y axes

2: corresponds to "absolute

measurement"

0x2047

0x0

u8

Output value

0: corresponds to "angle"

0x2048

0x0

u8

Axis selection for Veff & aPeak

7: corresponds to "X/Y/Z" activated

0x2049

0x0

u8

FIR filter for vibration measurement

5: corresponds to "10...400 Hz"

0x204A

0x0

u8

Measuring range for vibration

measurement

2: corresponds to "8g"

0x6000

0x0

u16

Resolution

100d: corresponds to "0.1°"

Advertising
This manual is related to the following products: