2 applicative (sdo index 0x2040 - 0x207f) – ifm electronic JN2100 v.2.2.0 User Manual

Page 16

Advertising
background image

Inclination sensor JN

16

7.6.2 Applicative (SDO index 0x2040 - 0x207F)

SDO

index

Sub-

index

Type

Value

Unit

r/w

Reset

0x2040

0x0

u8

Flag for quadrant correction

0: off

1: on ± 180

2: on 0...360°

rw

0x2041

0x0

u8

Flag for heating

Flag = 0 heating off

Flag = 1 heating on

rw

0x2042

0x0

u8

Index teach values of the X/Y/Z axes

0: no change

1: set teach, relative measurement

2: reset teach, absolute measurement

rw

0x2043

0x0

u8

FIR filter for angle measurement

0: FIR deactivated

1: FIR 10 Hz

2: FIR 5 Hz

3: FIR 1 Hz

4: FIR 0.5 Hz

rw

0x2044

0x00

u8

Angle calculation

0: perpendicular

1: Euler

2: gimbal 1X

3: gimbal 1Y

rw

0x2045

0x00

u8

CAN 120 Ω terminating resistor

0: resistor deactivated

1: resistor activated

rw

0x2046

0x0

u8

Set zero point of the X / Y axes
0: unchanged
1: set zero (corresponds to the

relative measurement)
2: reset set zero (corresponds to the

absolute measurement)

rw

0x2047

0x0

u8

Output value
0: angle

1: Veff & aPeak
2: aVector X / Y / Z without DC part

(dynamic)
3: aVector X / Y / Z with DC part

(static)

automatic change to ± 2 g

rw

Advertising
This manual is related to the following products: