3 system settings (sdo index 0x4000 - 0x403f) – ifm electronic JN2100 v.2.2.0 User Manual

Page 17

Advertising
background image

UK

Inclination sensor JN

17

SDO

index

Sub-

index

Type

Value

Unit

r/w

Reset

0x2048

0x0

u8

Axis selection for Veff & aPeak
X axis active -> bit 2 = 1
X axis not active -> bit 2 = 0
Y axis active -> bit 1 = 1
Y axis not active -> bit 1 = 0
Z axis active -> bit 0 = 1
Z axis not active -> bit 0 = 0

rw

0x2049

0x0

u8

FIR filter for vibration measurement
0: FIR deactivated
1: FIR bandpass filter 0.1 - 1 Hz
2: FIR bandpass filter 0.1 - 10 Hz
3: FIR bandpass filter 1 - 10 Hz
4: FIR bandpass filter 2 - 400 Hz
5: FIR bandpass filter 10 - 400 Hz

rw

0x204A

0x0

u8

Measuring range for Veff & aPeak and

raw acceleration without DC part
0 : ± 2g
1 : ± 4g
2 : ± 8g

rw

0x207F

0x0

u8

Factory reset
1: make factory reset

rw

0x3000

0x0

ASCII

Programming key

rw

7.6.3 System settings (SDO index 0x4000 - 0x403F)

SDO

index

Sub-

index

Type

Value

Unit

r/w

Reset

0x4004

0x0

u8

MEMS self-test

Number sub-indices

r

0x4004

0x01

u8

Flag to activate the self-test
Flag = 1

start self-test

rw

Advertising