Procedure for non-vital, discoloured stumps
– mask the entire die with Liner to block out the dark colour of the underlying tooth stratum and, at the same time, to

attain an adequate degree of brightness.

– additionally, Stains white may be applied locally to the Liner surface to further increase the degree of brightness.

Practical Procedure

– Framework-fr

ee Restorations (Anterior Cr

own)

– The entire die surface has to be covered with an SR Nexco Liner layer of at least 150 µm. Thin

out the Liner towards the preparation margin.

– Do not separate polymerized SR Nexco Liner from the die.

– If desired, the translucency of the Liners 1–5 may be increased by using Liner clear or Liner

incisal.

Tips and tricks regarding the layering:

Liner incisal may be applied to the marginal area to
facilitate the transmission of light in the cervical area.
this measure provides a harmonious transition between
the gingiva and the restoration.

Polymerizing the Liner
for anterior crowns

Appliance

Time

Program

Precuring time per segment

Quick

20 s

For the parameters of other polymerization devices, please go to page 57.

Removal of the inhibition layer

thoroughly remove the resulting inhibition layer using a
disposable sponge (do not use a solvent); make sure that
the Liner surfaces are free of residue. make sure that the
Liner shows a slightly shiny surface.