Final polymerization, Finishing / polishing – Ivoclar Vivadent SR Nexco Paste User Manual

Page 54

Advertising
background image

54

fInaL PoLymErIzatIon

to minimize the inhibition layer, apply a covering but not too thick layer of Sr Gel prior to polyermization in a
Lumamat 100. then conduct the final polymerization in a Lumamat 100. the final processing of Sr nexco Gingiva is
limited to minor shape corrections and polishing of the surface.

fInISHInG / PoLISHInG

Finishing

after completion of the polymerization procedure, completely remove Sr Gel from the restoration using running water.
Use regular tungsten carbide burs and polishers to design and finish the surface and the surface texture. the inhibition
layer must be removed from the entire Sr nexco surface.

Finish with cross-cut tungsten carbide burs and stippling instruments.
Subsequently, polish with Universal Polishing Paste.

Apply a covering but not inappropriately thick coat of SR Gel and conduct the final polymerization.

Final polymerization

Appliance

Time

Program

Precuring time per segment

Quick

20 s

final polymerization

Lumamat 100

11 min

P2

For the parameters of other polymerization devices, please go to page 57.