General Information
– Cementation | Polymerization Parameters
PoLymErIzatIon ParamEtErS
Appliance
Manufacturer Opaquer
Dentin
Liner, Incisal,
Effect,
Margin
Gingiva
Stains
SR Connect
Final
polymerization
Quick
Lumamat 100
Ivoclar
Vivadent aG
20 s
Quick
P2/11 min
20 s
Quick
20 s
Quick
20 s
Quick
20 s
Quick
P2/11 min
P2/11 min
Spectramat
Ivoclar
Vivadent aG
5 min
5 min
2 min
5 min
2 min
2 min
5 min
Labolight
LV-III
Gc
5 min
2 min
2 min
5 min
2 min
3 min
5 min
Solidilite V
Shofu
3 min
1 min
1 min
3 min
1 min
3 min
5 min
Visio Beta
Vario
3m
7 min
no vacuum
4x 20 s
Visio alfa
4x 20 s
Visio alfa
4x 20 s
Visio alfa
4x 20 s
Visio alfa
4x 20 s
Visio alfa
4x 20 s
no vacuum
HiLite
Heraeus
Kulzer
180 s
90 s
90 s
90 s
90 s
90 s
180 s
– Regular maintance and functional checks of the polymerization appliances are required.
– Appliances for tack-curing: Quick (Ivoclar Vivadent AG), HiLite pre (Heraeus Kulzer), Visio Alfa (3M ESPE),
Sublite V (Shofu), Steplight SL-I (GC).