Ivoclar Vivadent SR Nexco Paste User Manual

Page 52

Advertising
background image

52

Opaquer
polyermization

Appliance

Time

Program

Precuring time per segment

Quick

20 s

final polymerization

Lumamat 100

11 min

P2

For the parameters of other polymerization devices, please go to page 57.

oPaQUEr aPPLIcatIon to VEnEEr tHE GInGIVaL PortIonS

Gingiva opaquer layer

Extrude the desired amount of the ready-to-use opaquer paste from the syringe and spread it out slightly on the mixing
pad using a brush. apply the first opaquer layer (wash) thinly using the brush. If retention beads are used, make sure to
thoroughly smooth out or fill up any roughness on the metal surface, since the wash layer represents the most important
bond between the metal and the composite. Subsequently, precure the wash for 20 seconds per tooth using the Quick.
apply the second opaquer layer. the metal framework should now be entirely covered with opaquer. make sure to apply
as much material as necessary and as little material as possible. Subsequently, polymerize in a Lumamat 100.

Apply the first Gingiva Opaquer layer (wash) thinly with a brush and precure with a Quick curing light.

Entirely cover the gingival area with the second Opaquer layer and polymerize in a Lumamat 100.

– If a metal margin has been designed, thin out the Opaquer towards the metal margin to ensure a clean

transition between metal and composite.

– If a smooth surface is preferred, lightly tap the top of the surface with a spatula.

– Using a probe, check opaquer for complete polymerization in critical areas and cure again as necessary.