1.8 BLUETOOTH® MODULE


Rhino-NET™/RF-3 EU BT Low Temp model is equipped with a Bluetooth® module for radio
communications to other devices which use this standard, for example a Gryphon BT
scanner, printers, etc.

Connections are not guaranteed at temperatures below 0° C.

1.9 CONNECTORS


All external connectors for Rhino-NET™ are located on the bottom of the unit.

The COM 1 port connects any EIA RS232 device. It also can be wired to connect a scanner
powered by an external power source.

The COM 2/Scanner port has been designed to connect and power a scanner with 5V power
supply on pin 9. This port can also be used to connect RS232 devices that are not influenced
by the 5V provided on pin 9 of the COM2/Scanner connector.
The maximum current draw allowed is 0.5 A @ 5 VDC; therefore, do not attach scanners or
other devices that exceed this value.

The following tables illustrate the pinout for COM1 and COM2/Scanner ports respectively:

COM1

Pin

Function

Type

1 DCD

Input

2

RX

Input

3

TX

Output

4

DTR

Output

5

GND

Ground

6

DSR

Input

7

RTS

Output

8

CTS

Input

9

RIN

Input


COM2/Scanner

Pin

Function

Type

1 DCD

Input

2

RX

Input

3

TX

Output

4

DTR

Output

5

GND

Ground

6

DSR

Input

7

RTS

Output

8

CTS

Input

9

+5V

Supply voltage