Hardware reset, Software reset, Battery warning messages – Datalogic Scanning Rhino-NET 40012 User Manual

Page 33

Advertising
background image

USE AND OPERATION

3

3.3.1 Hardware

Reset


In case the Rhino-NET™ terminal locks up and cannot be unlocked a hardware reset can be
performed as follows:

1. Turn off the Rhino-NET™ power switch.

2. Press and hold the FUNC key while turning on the power switch.

3. Release the FUNC key.

CAUTION

All data in the volatile memory will be lost when implementing this
procedure.


3.3.2 Software

Reset


A software reset can be performed on the Rhino-NET™ terminal as follows:

1. Turn off the Rhino-NET™ power switch.

2. Press and hold the CTRL key while turning on the power switch. All data in the

volatile memory will be preserved.

3. Release the CTRL key.


3.4 BATTERY WARNING MESSAGES


Whenever the Power Switch is turned on, Rhino-NET™ performs a check on the backup and
RTC Clocks and if any anomaly or a low battery condition is encountered, a warning
message is displayed. You can continue working after closing the message window.

Figure 19 - Example Battery Warning Message





19