Troubleshooting, 5 troubleshooting – Datalogic Scanning Rhino-NET 40012 User Manual

Page 45

Advertising
background image

TROUBLESHOOTING

5

5 TROUBLESHOOTING


CAUTION

The only internal components that personnel not belonging to Datalogic or
ARC technical support can add or replace by removing Rhino-NET™'s
cover are PCMCIA cards as described in chapter 1.6.
Opening Rhino-NET™ may damage internal components and causes
warranty loss.


Before sending Rhino-NET™ to technical support, the Customer has the responsibility of
saving all data and configuration settings (backup). Datalogic's only responsibility is the
recovery of the exact hardware configuration of Rhino-NET™.

Problem Possible

Solution

Rhino-NET™ does not respond to
any type of input (keyboard entry,
barcode scanning).

- Wait some minutes, since the timeout of TCP/IP

may be waiting for a transaction occurred in an
area with no radio coverage (during such timeouts
Rhino-NET™ is suspended). Timeout normally
takes 2 minutes.

- If problem persists, perform a software reset
- If problem still persists, perform a hardware reset

Rhino-NET™ does not switch on:
the red LED on the keyboard is off.

Ensure that Rhino-NET™ is correctly powered.
Check fuse's integrity.

Rhino-NET™ does not switch on:
the red LED on the keyboard is on.

Contact the nearest Datalogic distributor for technical
assistance.

The boot seems to be correct, but
Rhino-NET™ does not connect to
the wireless LAN or cannot reach
the host.

Check configuration correctness, since one of the
following conditions may have occurred:
- Rhino-NET™ is out of access point coverage area;
- radio configuration files (SSID, Wep Encription,

safety parameters, etc.) may have been set
incorrectly (refer to the radio card manual);

- TCP/IP configuration files may have been set

incorrectly (Rhino-NET™ IP address, Subnet Mask,
Default Router, etc.)

- The configuration files of the running application

may have been set incorrectly (DL-TCL for CE,
Web Client)

- The radio may be broken or the antenna connector

is disconnected.











31