TECHNICAL FEATURES

6

6 TECHNICAL

FEATURES


Electrical Features

Power

Internal wide range power supply (11-60 VDC)
Transient spike and over current/voltage protected
Reverse polarity protected
Connects directly to vehicle battery

Control Switches

Power ON/OFF, contrast and brightness, beeper volume

Status Indicator Lights

Caps Lock and Power

Hardware Features

Microprocessor

PXA 255 @ 400 MHz

Operating System

Windows CE 4.2

System RAM Memory

64 MB

System Flash Memory

32 MB

Real-Time Clock

Time and date stamping under software control

Mechanical Features

Dimensions

320 X 250 X 90 mm

Weight

4 Kg Approx. (excluding mounting bracket)

Display

Color TFT LCD with backlight

Keyboard

57-key alphanumeric keyboard with illumination and audible
key beep

Speaker

2 piezoelectric buzzers

LED

2 keyboard LEDs

Environmental Features

Operating Temperature

-30 to +50 °C (-22 to 122 °F)

Storage Temperature

-30 to +70 °C (-22 to 158 °F)

Environmental sealing

IP65

Operating Humidity

Up to 90% non-condensing

Random Vibration

EN 60068-2-64 Frequency Range 5-1000 Hz;
acceleration RMS : 3.1 g; initial slope: 26 dB/oct 5-10 Hz,
final slope: -3 dB/oct 10-1000 Hz

ESD

EN 61000-4-2

Shock

25 g, 6 ms duration, 1000 shock impacts per axis

Communication Features

Interfaces

2 RS232-C serial interfaces; COM2 with barcode option

Network

WLAN, 802.11b (Wi-Fi)

Antenna Integrated
Frequency range

Country dependent, typically 2.4 to 2.5 GHz

Bluetooth® *

Bluetooth® IEEE 802.15, Class 2, Version 1.2

Peripherals

Compatible Scanners

Dragon™ D; Dragon™ M with STAR-Modem™; Gryphon™ D,
Gryphon™ M with STAR-Modem™, Gryphon™ BT, Lynx™


*

available for Rhino-NET™/ RF-3 EU BT Low Temp only