5 default channel settings, 8 dmx menu, 1 patch – LSC Lighting GenVI User Manual

Page 17: Default channel settings, Dmx menu, Patch

Advertising
background image

GenVI Dimmer

Menu System

Operator Manual V1.0

Page 13

level whenever any valid DMX signal is detected. These channels will remain on for a
programmable “hold time” when DMX is no longer detected. GenVI switched output
provides direct power by utilising relays guaranteeing there are absolutely no
electronics in the circuit to interfere with connected loads.

3.7.5

Default Channel Settings

The default settings for channel parameters are;

ATTRIBUTE

DEFAULT SETTING

Min Level

0%

Max Level

100%

Fade Curve

Linear Curve

Control Source DMX Only

3.8 DMX MENU

Selecting Config, DMX provides menus for:

Patching DMX.

Editing and activating the DMX Loss (D) memory.

Enabling and time setting the Auto Power function.

Viewing the Input DMX signal.

3.8.1

Patch

Each GenVI dimmer unit numbers its channels from channel 1 through to channel 12.
The patch menu allows you to patch (connect) DMX slots (addresses) from your DMX lighting
controller to GenVI channel numbers. Patches are often performed in contiguous blocks of
addresses.

Note: The DMX Address button on the “DMX Address” home page provides a rapid method
of patching all of the dimmers in one GenVI unit to sequential DMX slots, starting from a DMX
address that you select. See section 3.3.1.1

The “Patch” menu allows you to individually patch dimmers channels to DMX slots. Individual
patches are required when;

A particular DMX slot number from the lighting controller is to control a particular GenVI

dimmer channel number.

A single DMX slot number is to control multiple GenVI channel numbers.


To individually patch dimmers channels to DMX addresses press Config, DMX, Patch.

Advertising